2.9.1 Electrical specifications
2.9.1 Electrical specifications
Item | Specification | |
---|---|---|
CPU type: SPARC64 X | CPU type: SPARC64 X+ | |
Input voltage | 200 to 240 VAC |
|
Number of power cords | 2 (1 for each PSU) |
|
Power cord length | Maximum length of 3.0 m (9.8 ft.) | |
Redundancy | 1+1 redundant configuration | |
Frequency | 50 Hz/60 Hz, single phase |
|
Maximum input current (*1) | 14.8 A | 16.0 A |
Maximum power consumption | 2,891 W | 3,208 W |
Apparent power | 2,950 VA | 3,273 VA |
Rush current (*2) | 45 A peak or less |
|
Leakage current (*2) | 1.75 mA or less | |
*1 The current that flows through each power cord in a redundant configuration is half the value listed in Table 2-8. *2 The value is per power cord. |
Item | Specification | |
---|---|---|
Input voltage of 100 to 120 VAC | Input voltage of 200 to 240 VAC | |
Number of power cords | 2 (1 for each PSU) |
2 (1 for each PSU) |
Power cord length | Maximum length of 3.0 m (9.8 ft.) | Maximum length of 3.0 m (9.8 ft.) |
Redundancy | 1+1 redundant configuration | 1+1 redundant configuration |
Frequency | 50 Hz/60 Hz, single phase |
50 Hz/60 Hz, single phase |
Maximum input current (*1) | 2.9 A | 1.4 A |
Maximum power consumption | 279 W | 270 W |
Apparent power | 284 VA |
276 VA |
Rush current (*2) | 40 A peak or less |
40 A peak or less |
Leakage current (*2) | 1.75 mA or less | 1.75 mA or less |
*1 The current that flows through each power cord in a redundant configuration is half the value listed in Table 2-9. *2 The value is per power cord. |
< Previous Page | Next Page >