Appendix A Cards That Support PCI Hot Plug and Dynamic Reconfiguration
Appendix A Cards That Support PCI Hot Plug and Dynamic Reconfiguration
This appendix describes cards that support PCI Hot Plug and Dynamic Reconfiguration.
The SPARC M10-4/M10-4S on-board PCI slot and PCI expansion unit support active replacement and active addition of PCI cards using PCI Hot Plug (PHP). The SPARC M10-1 on-board PCI slot does not support this function.
The SPARC M10-4S supports the dynamic reconfiguration (DR) function for a physical partition. The SPARC M10-4/M10-1 do not support this function. If a card that does not support the dynamic reconfiguration function is mounted in a physical partition, dynamic reconfiguration (DR) for the physical partition cannot be performed. In that case, perform replacement or maintenance in the inactive state.
Table A-1 lists the PHP/DR supporting cards that have Fujitsu product IDs. Table A-2 lists the PHP/DR supporting cards that have Oracle product IDs.
The SPARC M10-4/M10-4S on-board PCI slot and PCI expansion unit support active replacement and active addition of PCI cards using PCI Hot Plug (PHP). The SPARC M10-1 on-board PCI slot does not support this function.
The SPARC M10-4S supports the dynamic reconfiguration (DR) function for a physical partition. The SPARC M10-4/M10-1 do not support this function. If a card that does not support the dynamic reconfiguration function is mounted in a physical partition, dynamic reconfiguration (DR) for the physical partition cannot be performed. In that case, perform replacement or maintenance in the inactive state.
Table A-1 lists the PHP/DR supporting cards that have Fujitsu product IDs. Table A-2 lists the PHP/DR supporting cards that have Oracle product IDs.
Category | Name | Product ID | Driver Name Software Product Name |
PHP: PCI Hot Plug | DR: Dynamic Reconfiguration | Path Redundancy Software |
|||
---|---|---|---|---|---|---|---|---|---|
Active Replacement | Active Addition | Active Replacement | Active Addition | Suspend/Resume Processing Time (*1) | |||||
Link | PCI expansion unit connection card | SPME8LK1F | None | Supported | Supported (*2) | Supported | Supported | 0.1 sec. (*3) | None |
LAN | Dual Gigabit Ethernet card (MMF) | SP1X7GD2F | igb | Supported | Supported | To be supported | Oracle Solaris standard multi-path function (IPMP), or PRIMECLUSTER GLS 4.3A20 or later | ||
Dual Gigabit Ethernet card (MMF) | SP1X7GD1F | igb | Supported | Supported | To be supported | ||||
Quad Gigabit Ethernet card (UTP) | SP1X7GQ2F | igb | Supported | Supported | Supported | Supported | 0.8 sec. | ||
Quad Gigabit Ethernet card (UTP) | SP1X7GQ1F | igb | Supported | Supported | Supported | Supported | 0.8 sec. | ||
Dual 10 Gigabit Ethernet card | SE1X7HE3G | ixgbe | Supported | Supported | Supported (*4) | Supported (*4) | 0.4 sec. | ||
Dual 10Gigabit Ethernet card (10GBase-T) | SP1X7HF1F | ixgbe | Supported | Supported | Supported (*4) | Supported (*4) | 0.4 sec. | ||
Quad 10 Gigabit Ethernet card | SP1X7HH1F | i40e | Supported | Not supported | Supported (*4) | Supported (*4) | 1.0 sec. | ||
Dual 25 Gigabit Ethernet card | SP1X7JD1F | bnxt | Not supported | Not supported | - | - | - | ||
Dual 40 Gigabit Ethernet card | SP1X7HG1F | i40e | Supported (*5) | Not supported | Supported (*5) | Supported (*5) | 1.5 sec. | ||
FCoE | Dual-channel 10Gbps FCoE card (for optical cable) | SP1X7FAR2F | qlc, qlcnic | Not supported | Not supported | Supported (*6) | Supported (*6) | 20 sec. (*7) |
Network redundancy: Oracle Solaris standard multi-path function (IPMP) FC redundancy: Oracle Solaris standard multi-path function (mpxio) or ETERNUS multi-path driver 3.1.0 or later |
Dual-channel 10Gbps FCoE card (for Copper Twinax cable) | SP1X7FAS2F | qlc, qlcnic | Not supported | Not supported | Supported (*6) | Supported (*6) | 20 sec. (*7) |
||
Dual-channel 10Gbps FCoE card (for optical cable) | SP1X7FBR2F | emlxs, oce | Not supported | Not supported | Supported (*8) | Supported (*8) | |||
Dual-channel 10Gbps FCoE card (for Copper Twinax cable) | SP1X7FBS2F | emlxs, oce | Not supported | Not supported | Supported (*8) | Supported (*8) | |||
Dual 10Gbps FCoE card (for optical cable) | SE0X7EF12F | qlc, qlge | Supported | Supported (*9) | Supported (*10) | Supported (*10) | |||
Dual 10Gbps FCoE card (for Copper Twinax cable) | SE0X7EC12F | qlc, qlge | Supported | Supported (*9) | Supported (*10) | Supported (*10) | |||
FC | Single-channel 8Gbps Fibre Channel card | SE0X7F21F | qlc | Supported | Supported (*11) | Supported | Supported | 10 sec. (*7) |
Oracle Solaris standard multi-path function (mpxio) or ETERNUS multi-path driver 3.1.0 or later |
Dual-channel 8Gbps Fibre Channel card | SE0X7F22F | qlc | Supported | Supported (*11) | Supported | Supported | 20 sec. (*7) |
||
Single-channel 8Gbps Fibre Channel card | SE0X7F31F | emlxs | Supported | Supported | Supported | Supported | 18.5 sec. | ||
Dual-channel 8Gbps Fibre Channel card | SE0X7F32F | emlxs | Supported | Supported | Supported | Supported | 37 sec. |
||
Dual-channel 32 Gbps Fibre Channel card | SP1X7FAC2F | qlc | Supported | Supported | Not supported | Not supported | - | ||
Dual-channel 32 Gbps Fibre Channel card | SP1X7FBC2F | emlxs | Supported | Supported | Supported | Supported | 37 sec. |
||
Dual-channel 16Gbps Fibre Channel card (SR SFP+) | SP1X7FAA2F | qlc | Supported | Supported (*9) | Supported | Supported | 20 sec. (*7) |
||
Dual-channel 16Gbps Fibre Channel card (LR SFP+) | SP1X7FAB2F | qlc | Supported | Supported (*9) | Supported | Supported | 20 sec. (*7) |
||
Dual-channel 16Gbps Fibre Channel card (SR SFP+) | SP1X7FBA2F | emlxs | Supported | Supported | Supported | Supported | 37 sec. (*12) |
||
Quad-channel 16Gbps Fibre Channel card (SR) | SP0X7FAA4F | qlc | Supported | Supported | Not supported | Not supported | - | ||
SAS | 12Gbps SAS card | SP1X7SA3F | lsc | Supported (*13) | Supported (*13) | Supported (*14) | Supported (*14) | 2 sec. |
Oracle Solaris standard multi-path function (mpxio) |
SAS card | SE0X7SA1F | FUJITSU ULTRA LVD SCSI Host Bus Adapter Driver 2.1 Update1 or later | Supported | Supported (*9) | Supported | Supported | 0.2 sec. | For ETERNUS connection, ETERNUS multi-path driver 3.0 or later | |
6Gbps SAS card | SE0X7SA2F | mpt_sas | Supported (*15) | Supported (*15) | Supported (*16) | Supported (*16) | 0.2 sec. | Oracle Solaris standard multi-path function (mpxio) | |
FLASH | 3.2 TB Flash Accelerator Card | 7119601(7119603) | nvme | Not supported | Not supported | Not supported | Not supported | - | |
Flash Accelerator F320 card | SP1X7Y41F | nvme | Not supported | Not supported | Not supported | Not supported | - | ||
Flash Accelerator F160 card | SP1X7Y31F | nvme | Supported | Supported | Supported (*17) | Supported (*17) | 6 sec. |
None (*18) | |
Flash Accelerator F80 card | SP1X7Y21F | mpt_sas | Supported | Supported | Supported | Supported | 0.2 sec. | None (*19) | |
Flash Accelerator F40 card | SP1X7Y11F | mpt_sas | Supported | Supported | Supported | Supported | 0.2 sec. | ||
Infini Band |
Dual Port InfiniBand 4x QDR card | SP1X7BA12F | hermon | Not supported | Not supported | Not supported | Not supported | - | Oracle Solaris standard multi-path function (IPMP) |
Dual Port InfiniBand 4x QDR card | SE1X7BA12F | hermon | Not supported | Not supported | Not supported | Not supported | - | ||
Graphic | Graphics card | SP0X7GR1F | mko (TSI) | Not supported | Not supported | Not supported | Not supported | - | None |
-: Not applicable *1 The suspend/resume processing time means the time required for the suspend/resume processing per PCI card. Calculate the total suspend/resume processing time for the PCI cards to be used. *2 To be supported on Oracle Solaris 11.2 SRU 11.2.2.8.0 and later and Oracle Solaris 10 1/13 150400-18 and later. *3 Add up the suspend/resume processing time for all the PCI cards mounted in the PCI expansion unit. *4 In a configuration that uses this card to assign SR-IOV (VF), DR is restricted. *5 In 2x40 mode or 2x2x10 mode, the root domain must be restarted because the QCU tool is used to switch modes. *6 To use the Ethernet function (qlcnic driver) in Oracle Solaris 10, apply 149167-07 or later. *7 When the suspend/resume processing occurs as the port is being linked up, it takes about 3 seconds with a 1-port card and about 5 seconds with a 2-port card. *8 To be supported on Oracle Solaris 11.2 SRU 11.2.2.8.0 and later and Oracle Solaris 10 1/13 and later. *9 Active addition of this card to a PCI Expansion Unit by PHP is not available right after the active addition of the PCI Expansion Unit. *10 To be supported Oracle Solaris 11.2 SRU 11.2.2.8.0 and later. Oracle Solaris 10 is not supported. *11 For active addition of this card to a PCI expansion unit by PHP right after active addition of the PCI expansion unit, it is necessary to perform the following setting and restart the I/O domains beforehand. Add # in front of the following description in /kernel/drv/qlc.conf, and reboot the I/O domains. pci-max-read-request=2048; *12 The processing time for each card is 10 seconds in Oracle Solaris 11.3 or later and Oracle Solaris 10 1/13 149173-06 or later. *13 Active addition and active replacement for a PCI Expansion Unit are not available. *14 Supported by Oracle Solaris 11.3 and later *15 PHP disconnection processing may fail. If disconnection processing fails, perform inactive replacement. *16 Disconnection processing may return the busy status and fail in a configuration in which an expansion file unit is connected. Perform the disconnection processing after suspending the fmd service. Example: Suspension/resumption of the fmd service (Suspension) # svcadm disable svc:/system/fmd:default (Resumption) # svcadm enable svc:/system/fmd:default *17 In an environment where active maintenance with DR is performed, the function to use this card as the system volume is supported on Oracle Solaris 11.3 SRU 11.3.5.6.0 and later. *18 When data must be inherited after card replacement with PHP, configure the disk, etc. that is the card connection destination in a redundant configuration beforehand by mirroring the disk, etc. with ZFS, etc. *19 When data must be inherited after card replacement with PHP, configure the disk, etc. that is the card connection destination in a redundant configuration beforehand by mirroring the disk, etc. with ZFS, GD, etc. |
Category | Name | Factory-Mounted Product ID When Shipped (Expanded-on-Site Product ID) |
Driver Name Software Product Name |
PHP: PCI Hot Plug | DR: Dynamic Reconfiguration | Path Redundancy Software |
||||
---|---|---|---|---|---|---|---|---|---|---|
Active Replacement | Active Addition | Active Replacement | Active Addition | Suspend/Resume Processing Time (*1) | ||||||
Link | Link card kit | 7105513 (7105576) |
None | Supported | Supported (*2) | Supported | Supported | 0.1 sec. (*3) | None | |
LAN | Sun Dual Port GbE PCIe 2.0 Low Profile Adapter, MMF | 7100482 (7100481) |
igb | Supported | Supported | To be supported | Oracle Solaris standard multi-path function (IPMP) | |||
Sun Quad Port GbE PCIe 2.0 Low Profile Adapter,UTP | 7100479 (7100477) |
igb | Supported | Supported | Supported | Supported | 0.8 sec. | |||
Sun Dual Port 10GBase-T Adapter | 7100563 (7100488) |
ixgbe | Supported | Supported | Supported (*4) | Supported (*4) | 0.4 sec. | |||
Sun Dual 10 GbE SFP+ PCIe 2.0 Low Profile Adapter | 1109A-Z (X1109A-Z) |
ixgbe | Supported | Supported | Supported (*4) | Supported (*4) | 0.4 sec. | |||
PCIe Quad port GigE (copper) x8 lane card | 4447A-Z-N (X4447A-Z-N) |
nxge | Supported | Supported | Supported | Supported | 0.8 sec. | |||
PCI-E Low-Profile Dual GigE MMF | 7281A-2-N (X7281A-2-N) |
e1000g | Supported | Supported | Supported | Supported | 0.4 sec. | |||
Oracle Quad Port 10GBase-T Adapter | 7111182 (7111181) | i40e | Supported | Not supported | Supported (*4) | Supported (*4) | 1.0 sec. | |||
Oracle Dual Port 25 Gb Ethernet Adapter | 7118015 (7118016) |
bnxt | Not supported | Not supported | - | - | - | |||
Oracle Quad 10 Gb or Dual 40 Gb Ethernet Adapter | 7114148 (7114134) | i40e | Supported (*5) | Not supported | Supported (*5) | Supported (*5) | 1.5 sec. | |||
FCoE/FC | Oracle Storage Dual-Port 32 Gb Fibre Channel PCIe Low Profile HBA, QLogic | 7115460 (7115462) | qlc | Supported | Supported | Not supported | Not supported | - | ||
Oracle Storage Dual-Port 32 Gb Fibre Channel PCIe Low Profile HBA, Emulex | 7115459 (7115461) | emlxs | Supported | Supported | Supported | Supported | 37 sec. (*9) |
|||
Sun Storage 10 GbE PCIe FCoE Converged Network Adapter: QLogic low profile, dual port and SR optics | SG-PCIEFCOE2-Q-SR (7105381,SG-XPCIEFCOE2-Q-SR) |
qlc,qlge | Supported | Supported (*6) | Supported (*7) | Supported (*7) | Oracle Solaris standard multi-path function (IPMP), and Oracle Solaris standard multi-path function (mpxio) | |||
Sun Storage 10 GbE PCIe FCoE Converged Network Adapter: QLogic low profile, dual port and Twin-AX | SG-PCIEFCOE2-Q-TA (7105382,SG-XPCIEFCOE2-Q-TA) |
qlc,qlge | Supported | Supported (*6) | Supported (*7) | Supported (*7) | ||||
Sun Storage 16 Gb Fibre Channel PCIe Universal Host Bus Adapter, Qlogic | 7101673 (7101674) |
- | - | - | - | - | - | |||
with the 16 Gb FC short wave optics | with 7101675 (7101676) |
qlc | Supported | Supported (*6) | Supported | Supported | 20 sec. (*8) |
|||
with the 16 Gb FC long wave optics | with 7101679 (7101680) |
qlc | Supported | Supported (*6) | Supported | Supported | 20 sec. (*8) |
|||
with the 10 Gb FCoE short reach optics or TwinAx cables | with 7101677 (7101678) or TwinAx cables |
qlc,qlcnic | Supported | Supported (*6) | Supported (*9) | Supported (*9) | 20 sec. (*8) |
|||
Sun Storage 16 Gb Fibre Channel PCIe Universal Host Bus Adapter, Emulex | 7101683 (7101684) |
- | - | - | - | - | - | |||
with the 16 Gb FC short wave optics | with 7101685 (7101686) |
emlxs | Supported | Supported | Supported | Supported | 37 sec. (*10) |
|||
with the 10 Gb FCoE short reach optics or TwinAx cables | with 7101687 (7101688) |
emlxs,oce | Supported | Supported (*6) | Supported (*11) | Supported (*11) | ||||
8 Gb FC PCIe, QLogic, Dual Port |
SG-PCIE2FC-QF8-Z (SG-XPCIE2FC-QF8-N) |
qlc | Supported | Supported (*12) | Supported | Supported | 20 sec. (*8) |
|||
8 Gb FC PCIe, QLogic, Single Port |
SG-PCIE1FC-QF8-Z (SG-XPCIE1FC-QF8-N) |
qlc | Supported | Supported (*12) | Supported | Supported | 10 sec. (*8) |
|||
8 Gb FC PCIe, Emulex, Dual Port |
SG-PCIE2FC-EM8-Z (SG-XPCIE2FC-EM8-N) |
emlxs | Supported | Supported | Supported | Supported | 37 sec. |
|||
8 Gb FC PCIe, Emulex, Single Port |
SG-PCIE1FC-EM8-Z (SG-XPCIE1FC-EM8-N) |
emlxs | Supported | Supported | Supported | Supported | 18.5 sec. | |||
SAS | Oracle Storage 12Gb SAS PCIe HBA,external: 8port | 7110118 (7110119) | lsc | Supported (*13) | Supported (*13) | Supported (*14) | Supported (*14) | 2 sec. |
Oracle Solaris standard multi-path function (mpxio) | |
Sun Storage 6 Gb SAS PCIe HBA: 8 ports, external | SG-SAS6-EXT-Z (7105387,SGX-SAS6-EXT-Z) |
mpt_sas | Supported | Supported | Supported | Supported | 0.2 sec. | Oracle Solaris standard multi-path function (mpxio) | ||
Sun StorageTek 8-port External SAS PCI-Express Host Bus Adapter | SG-PCIE8SAS-E-Z-N (SG-XPCIE8SAS-E-Z-N) |
mpt_sas | Supported | Supported | Supported | Supported | 0.2 sec. | |||
FLASH | Fujitsu 3.2 TB Flash Accelerator Card | 7119601 (7119603) | nvme | Not supported | Not supported | Not supported | Not supported | - | ||
Oracle Flash Accelerator F320 PCIe Card | 7113825 (7113826) | nvme | Not supported | Not supported | Not supported | Not supported | - | |||
Flash Accelerator F160 Card | 7110864 (7110865) |
nvme | Supported | Supported | Supported (*15) | Supported (*15) | 6 sec. |
None (*16) | ||
Flash Accelerator F80 PCIe Card: 800GB, eMLC | 7107091 (7107092) |
mpt_sas | Supported | Supported | Supported | Supported | 0.2 sec. | None (*16) | ||
Flash Accelerator F40 card | 7104480 (7104482) |
mpt_sas | Supported | Supported | Supported | Supported | 0.2 sec. | |||
IB | Oracle Dual port QDR InfiniBand Adapter M3 | 7104073 (7104074) |
hermon | Not supported | Not supported | Not supported | Not supported | - | Oracle Solaris standard multi-path function (IPMP), and Oracle Solaris standard multi-path function (mpxio) | |
Sun InfiniBand QDR Host Channel Adapter PCIe: low profile | 4242A (X4242A) |
hermon | Supported | Supported | Not supported | Not supported | - | |||
-: Not applicable *1 Apply the total suspend/resume processing time for the PCI cards to be used. *2 To be supported on Oracle Solaris 11.2 SRU 11.2.2.8.0 and later and Oracle Solaris 10 1/13 150400-18 and later. *3 Add the suspend/resume processing time for all the PCI cards mounted in the PCI expansion unit to the suspend/resume processing time for the link card. *4 In a configuration that uses this card to assign SR-IOV (VF), DR is restricted. *5 In 2x40 mode or 2x2x10 mode, the root domain must be restarted because the QCU tool is used to switch modes. *6 Active addition of this card to a PCI Expansion Unit by PHP is not available right after the active addition of the PCI Expansion Unit. *7 To be supported Oracle Solaris 11.2 SRU 11.2.2.8.0 and later. Oracle Solaris 10 is not supported. *8 When the suspend/resume processing occurs as the port is being linked up, it takes about 3 seconds with a 1-port card and about 5 seconds with a 2-port card. *9 To use the Ethernet function (qlcnic driver) in Oracle Solaris 10, apply 149167-07 or later. *10 The processing time for each card is 10 seconds in Oracle Solaris 11.3 or later and Oracle Solaris 10 1/13 149173-06 or later. *11 To be supported on Oracle Solaris 11.2 SRU 11.2.2.8.0 and later and Oracle Solaris 10 1/13 and later. *12 For active addition of this card to a PCI expansion unit by PHP right after active addition of the PCI expansion unit, it is necessary to perform the following setting and restart the I/O domains beforehand. Add # in front of the following description in /kernel/drv/qlc.conf, and reboot the I/O domains. pci-max-read-request=2048; *13 Active addition and active replacement for a PCI Expansion Unit are not available. *14 Supported by Oracle Solaris 11.3 and later *15 In an environment where active maintenance with DR is performed, the function to use this card as the system volume is supported on Oracle Solaris 11.3 SRU 11.3.5.6.0 and later. *16 When data must be inherited after card replacement with PHP, configure the disk, etc. that is the card connection destination in a redundant configuration beforehand by mirroring the disk, etc. with ZFS, etc. |