Skip to main content

3.2.3 XCP 2044 or Earlier


3.2.3 XCP 2044 or Earlier
Table 3-5  Maximum Number of Each Type of Mounted PCI Card: SPARC M10-4S With XCP 2044 or Earlier (Fujitsu Product ID)
Type Product Name Product ID Maximum Number Mounted
Without PCI Expansion Unit With PCI Expansion Unit
Link PCI expansion unit connection card SPME8LK1F - 2CPU:3 (#0,#3,#7)
4CPU:5 (#0,#1,#3,#5,#7)
LAN Dual Gigabit Ethernet card (MMF) SP1X7GD2F 8 2CPU:38
4CPU:58
  Dual Gigabit Ethernet card (MMF) SP1X7GD1F 8 2CPU:38
4CPU:58
  Quad Gigabit Ethernet card (UTP) SP1X7GQ2F 8 2CPU:38
4CPU:58
  Quad Gigabit Ethernet card (UTP) SP1X7GQ1F 8 2CPU:38
4CPU:58
  Dual 10Gigabit Ethernet card
(10GBase-T)
SP1X7HF1F 2CPU:3 (#0,#3,#7)
4CPU:5 (#0,#1,#3,#5,#7)
2CPU:2 (#0,#3,#7)
4CPU:4 (#0,#1,#3,#5,#7)
PCI expansion unit mounting not possible
  Dual 10 Gigabit Ethernet card SE1X7HE3G 2CPU:3 (#0,#3,#7)
4CPU:5 (#0,#1,#3,#5,#7)
2CPU:2 (#0,#3,#7)
4CPU:4 (#0,#1,#3,#5,#7)
PCI expansion unit mounting not possible
  Quad 10 Gigabit Ethernet card SP1X7HH1F - -
  Dual 40 Gigabit Ethernet card SP1X7HG1F - -
FCoE Dual 10Gbps FCoE card (for optical cable) SE0X7EF12F 2CPU:3 (#0,#3,#7)
4CPU:5 (#0,#1,#3,#5,#7)
2CPU:2 (#0,#3,#7)
4CPU:4 (#0,#1,#3,#5,#7)
PCI expansion unit mounting not possible
  Dual 10Gbps FCoE card (for Copper Twinax cable) SE0X7EC12F 2CPU:3 (#0,#3,#7)
4CPU:5 (#0,#1,#3,#5,#7)
2CPU:2 (#0,#3,#7)
4CPU:4 (#0,#1,#3,#5,#7)
PCI expansion unit mounting not possible
  Dual-channel 10Gbps FCoE card (for optical cable) (QLogic) SP1X7FAR2F 2CPU:3 (#0,#3,#7)
4CPU:5 (#0,#1,#3,#5,#7)
2CPU:2 (#0,#3,#7)
4CPU:4 (#0,#1,#3,#5,#7)
PCI expansion unit mounting not possible
  Dual-channel 10Gbps FCoE card (for Copper Twinax cable) (QLogic) SP1X7FAS2F 2CPU:3 (#0,#3,#7)
4CPU:5 (#0,#1,#3,#5,#7)
2CPU:2 (#0,#3,#7)
4CPU:4 (#0,#1,#3,#5,#7)
PCI expansion unit mounting not possible
  Dual-channel 10Gbps FCoE card (for optical cable) (Emulex) SP1X7FBR2F 2CPU:3 (#0,#3,#7)
4CPU:5 (#0,#1,#3,#5,#7)
2CPU:2 (#0,#3,#7)
4CPU:4 (#0,#1,#3,#5,#7)
PCI expansion unit mounting not possible
  Dual-channel 10Gbps FCoE card (for Copper Twinax cable) (Emulex) SP1X7FBS2F 2CPU:3 (#0,#3,#7)
4CPU:5 (#0,#1,#3,#5,#7)
2CPU:2 (#0,#3,#7)
4CPU:4 (#0,#1,#3,#5,#7)
PCI expansion unit mounting not possible
FC Dual-channel 32 Gbps Fibre Channel card SP1X7FAC2F - -
  Dual-channel 32 Gbps Fibre Channel card SP1X7FBC2F - -
  Dual-channel 16Gbps Fibre Channel card (SR SFP+) SP1X7FAA2F 8 2CPU:38
4CPU:58
  Dual-channel 16Gbps Fibre Channel card (LR SFP+) SP1X7FAB2F 8 2CPU:38
4CPU:58
  Dual-channel 16Gbps Fibre Channel card (SR SFP+) SP1X7FBA2F 2CPU:3 (#0,#3,#7)
4CPU:5 (#0,#1,#3,#5,#7)
2CPU:2 (#0,#3,#7)
4CPU:4 (#0,#1,#3,#5,#7)
PCI expansion unit mounting not possible
  Quad-channel 16Gbps Fibre Channel card (SR) SP0X7FAA4F - -
  Dual-channel 8Gbps Fibre Channel card (QLogic) SE0X7F22F 8 2CPU:38
4CPU:58
  Single-channel 8Gbps Fibre Channel card (QLogic) SE0X7F21F 8 2CPU:38
4CPU:58
  Dual-channel 8Gbps Fibre Channel card (Emulex) SE0X7F32F 2CPU:3 (#0,#3,#7)
4CPU:5 (#0,#1,#3,#5,#7)
2CPU:2 (#0,#3,#7)
4CPU:4 (#0,#1,#3,#5,#7)
PCI expansion unit mounting not possible
  Single-channel 8Gbps Fibre Channel card (Emulex) SE0X7F31F 2CPU:3 (#0,#3,#7)
4CPU:5 (#0,#1,#3,#5,#7)
2CPU:2 (#0,#3,#7)
4CPU:4 (#0,#1,#3,#5,#7)
PCI expansion unit mounting not possible
SAS 12Gbps SAS card (*1) SP1X7SA3F 8 2CPU:38
4CPU:58
  6Gbps SAS card SE0X7SA2F 8 2CPU:38
4CPU:58
  SAS card SE0X7SA1F 8 2CPU:38
4CPU:58
FLASH 3.2 TB Flash Accelerator Card SP0X7Y42F - -
  Flash Accelerator F320 card SP1X7Y41F - -
  Flash Accelerator F160 card SP1X7Y31F - -
  Flash Accelerator F80 card SP1X7Y21F 8 2CPU:38
4CPU:58
  Flash Accelerator F40 card SP1X7Y11F 8 2CPU:38
4CPU:58
IB Dual Port InfiniBand 4x QDR card SP1X7BA12F 2CPU:3 (#0,#3,#7) (*2)
4CPU:5 (#0,#1,#3,#5,#7)
2CPU:2 (#0,#3,#7) (*2)
4CPU:4 (#0,#1,#3,#5,#7)
PCI expansion unit mounting not possible
  Dual Port InfiniBand 4x QDR card SE1X7BA12F 8 2CPU:38
4CPU:58
Graphic Graphics card (*3) SP0X7GR1F
1 (#1,#2)


1 (#1,#2)

PCI expansion unit mounting not possible
-: Not applicable

*1 To use the 12Gbps SAS card, the following SRU must be applied:
SRU 11.2.8.4.0 or later
*2 If this card is mounted in Slot#0 in a 2-CPU configuration, Slot#2 cannot be used. If this card is mounted in Slot#3, Slot#5 and #6 cannot be used.
*3 The supplied software installation CD-ROM is not supported in the Oracle Solaris 11.4 environment.
To use this in the Oracle Solaris 11.4 environment, you need to purchase the FUJITSU Software graphics card driver (order name: B23S0Y180).
Table 3-6  Maximum Number of Each Type of Mounted PCI Card: SPARC M10-4S With XCP 2044 or Earlier (Oracle Product ID)
Type Product Name Factory-Mounted Product ID When Shipped Maximum Number Mounted
(Expanded-on-Site Product ID) Without PCI Expansion Unit With PCI Expansion Unit
Link Link card kit 7105513 (7105576) - 2CPU:3 (#0,#3,#7)
4CPU:5 (#0,#1,#3,#5,#7)
LAN Sun Dual Port GbE PCIe 2.0 Low Profile Adapter, MMF 7100482 (7100481) 8 2CPU:38
4CPU:58
  Sun Quad Port GbE PCIe 2.0 Low Profile Adapter, UTP 7100479 (7100477) 8 2CPU:38
4CPU:58
  Sun Dual Port 10GBase-T Adapter 7100563 (7100488) 2CPU:3 (#0,#3,#7)
4CPU:5 (#0,#1,#3,#5,#7)
2CPU:2 (#0,#3,#7)
4CPU:4 (#0,#1,#3,#5,#7)
PCI expansion unit mounting not possible
  Sun Dual 10 GbE SFP+ PCIe 2.0 Low Profile Adapter 1109A-Z (X1109A-Z) 2CPU:3 (#0,#3,#7)
4CPU:5 (#0,#1,#3,#5,#7)
2CPU:2 (#0,#3,#7)
4CPU:4 (#0,#1,#3,#5,#7)
PCI expansion unit mounting not possible
  Oracle Quad Port 10GBase-T Adapter 7111182 (7111181) - -
  Oracle Quad 10 Gb or Dual 40 Gb Ethernet Adapter 7114148 (7114134) - -
  PCIe Quad port GigE (copper) x8 lane card 4447A-Z-N (X4447A-
Z-N)
2CPU:3 (#0,#3,#7)
4CPU:5 (#0,#1,#3,#5,#7)
2CPU:2 (#0,#3,#7)
4CPU:4 (#0,#1,#3,#5,#7)
PCI expansion unit mounting not possible
  PCI-E Low-Profile Dual GigE MMF 7281A-2-N (X7281A-
2-N)
2CPU:3 (#0,#3,#7)
4CPU:5 (#0,#1,#3,#5,#7)
2CPU:2 (#0,#3,#7)
4CPU:4 (#0,#1,#3,#5,#7)
PCI expansion unit mounting not possible
FC/FCoE Oracle Storage Dual-Port 32 Gb Fibre Channel PCIe Low Profile HBA, QLogic 7115460 (7115462) - -
  Oracle Storage Dual-Port 32 Gb Fibre Channel PCIe Low Profile HBA, Emulex 7115459 (7115461) - -
  Sun Storage 10 GbE PCIe FCoE Converged Network Adapter: QLogic low profile, dual port and SR optics SG-PCIEFCOE2-Q-
SR (7105381, SG-
XPCIEFCOE2-Q-SR)
2CPU:3 (#0,#3,#7)
4CPU:5 (#0,#1,#3,#5,#7)
2CPU:2 (#0,#3,#7)
4CPU:4 (#0,#1,#3,#5,#7)
PCI expansion unit mounting not possible
  Sun Storage 10 GbE PCIe FCoE Converged Network Adapter: QLogic low profile, dual port and Twin-AX SG-PCIEFCOE2-Q-
TA (7105382, SG-
XPCIEFCOE2-Q-TA)
2CPU:3 (#0,#3,#7)
4CPU:5 (#0,#1,#3,#5,#7)
2CPU:2 (#0,#3,#7)
4CPU:4 (#0,#1,#3,#5,#7)
PCI expansion unit mounting not possible
  Sun Storage 16 Gb Fibre Channel PCIe Universal Host Bus Adapter, Qlogic 7101673 (7101674) - -
    with the 16 Gb FC short wave optics with 7101675 (7101676) 8 2CPU:38
4CPU:58
    with the 16 Gb FC long wave optics with 7101679 (7101680) 8 2CPU:38
4CPU:58
    with the 10 Gb FCoE short reach optics or TwinAx cables with 7101677 (7101678)
or TwinAx cables
2CPU:3 (#0,#3,#7)
4CPU:5 (#0,#1,#3,#5,#7)
2CPU:2 (#0,#3,#7)
4CPU:4 (#0,#1,#3,#5,#7)
PCI expansion unit mounting not possible
  Sun Storage 16 Gb Fibre Channel PCIe Universal Host Bus Adapter, Emulex 7101683 (7101684) - -
    with the 16 Gb FC short wave optics with 7101685 (7101686) 2CPU:3 (#0,#3,#7)
4CPU:5 (#0,#1,#3,#5,#7)
2CPU:2 (#0,#3,#7)
4CPU:4 (#0,#1,#3,#5,#7)
PCI expansion unit mounting not possible
    with the 10 Gb FCoE short reach optics or TwinAx cables with 7101687 (7101688) 2CPU:3 (#0,#3,#7)
4CPU:5 (#0,#1,#3,#5,#7)
2CPU:2 (#0,#3,#7)
4CPU:4 (#0,#1,#3,#5,#7)
PCI expansion unit mounting not possible
 
8 Gb FC PCIe, QLogic, Dual Port
SG-PCIE2FC-QF8-Z
(SG-XPCIE2FC-QF8-
N)
8 2CPU:38
4CPU:58
 
8 Gb FC PCIe, QLogic, Single Port
SG-PCIE1FC-QF8-Z
(SG-XPCIE1FC-QF8-
N)
8 2CPU:38
4CPU:58
 
8 Gb FC PCIe, Emulex, Dual Port
SG-PCIE2FC-EM8-
Z (SG-XPCIE2FC-
EM8-N)
2CPU:3 (#0,#3,#7)
4CPU:5 (#0,#1,#3,#5,#7)
2CPU:2 (#0,#3,#7)
4CPU:4 (#0,#1,#3,#5,#7)
PCI expansion unit mounting not possible
 
8 Gb FC PCIe, Emulex, Single Port
SG-PCIE1FC-EM8-
Z (SG-XPCIE1FC-
EM8-N)
2CPU:3 (#0,#3,#7)
4CPU:5 (#0,#1,#3,#5,#7)
2CPU:2 (#0,#3,#7)
4CPU:4 (#0,#1,#3,#5,#7)
PCI expansion unit mounting not possible
SAS Oracle Storage 12 Gb SAS PCIe HBA, external: 8 port (*1) 7110118 (7110119) 8 2CPU:38
4CPU:58
  Sun Storage 6 Gb SAS PCIe HBA: 8 ports, external SG-SAS6-EXT-Z
(7105387, SGX-SAS6-
EXT-Z)
8 2CPU:38
4CPU:58
  Sun StorageTek 8-port External SAS PCI-Express Host Bus Adapter SG-PCIE8SAS-E-Z-
N (SG-XPCIE8SAS-
E-Z-N)
8 2CPU:38
4CPU:58
FLASH Fujitsu 3.2 TB Flash Accelerator Card 7119601 (7119603) - -
  Oracle Flash Accelerator F320 PCIe Card 7113825 (7113826) - -
  Flash Accelerator F160 PCIe Card 7110864 (7110865) - -
  Flash Accelerator F80 PCIe Card: 800GB, eMLC 7107091 (7107092) 8 2CPU:38
4CPU:58
  Flash Accelerator F40 card 7104480 (7104482) 8 2CPU:38
4CPU:58
IB Oracle Dual port QDR InfiniBand Adapter M3 7104073 (7104074) 2CPU:3 (#0,#3,#7) (*2)
4CPU:5 (#0,#1,#3,#5,#7)
2CPU:2 (#0,#3,#7) (*2)
4CPU:4 (#0,#1,#3,#5,#7)
PCI expansion unit mounting not possible
  Sun InfiniBand QDR Host Channel Adapter PCIe: low profile 4242A (X4242A) 8 2CPU:38
4CPU:58
Graphic Raptor GFX 550e (*3) -
1 (#1,#2)
1 (#1,#2)

PCI expansion unit mounting not possible
-: Not applicable

*1 To use the 12Gbps SAS card, the following SRU and card FW must be applied:
SRU 11.2.8.4.0 or later, card FW: 06.00.00.00 or later
*2 If this card is mounted in Slot#0 in a 2-CPU configuration, Slot#2 cannot be used. If this card is mounted in Slot#3, Slot#5 and #6 cannot be used.
*3 Sales Contact
EIZO Rugged Solutions, Inc.: ers-info@eizo.com
Shoshin Corporation: isï¼ shoshin.co.jp