Type | Product Name | Product ID | Maximum Number Mounted | |
---|---|---|---|---|
Without PCI Expansion Unit | With PCI Expansion Unit | |||
Link | PCI expansion unit connection card | SPME8LK1F | - | 2CPU:3 (#0,#3,#7) 4CPU:6 (#0,#1,#3,#5,#7,#9) |
LAN | Dual Gigabit Ethernet card (MMF) | SP1X7GD2F | 11 | 2CPU:41 4CPU:71 |
Dual Gigabit Ethernet card (MMF) | SP1X7GD1F | 11 | 2CPU:41 4CPU:71 |
|
Quad Gigabit Ethernet card (UTP) | SP1X7GQ2F | 11 | 2CPU:41 4CPU:71 |
|
Quad Gigabit Ethernet card (UTP) | SP1X7GQ1F | 11 | 2CPU:41 4CPU:71 |
|
Dual 10Gigabit Ethernet card (10GBase-T) |
SP1X7HF1F | 2CPU:3 (#0,#3,#7) 4CPU:6 (#0,#1,#3,#5,#7,#9) |
2CPU:2 (#0,#3,#7) 4CPU:5 (#0,#1,#3,#5,#7,#9) PCI expansion unit mounting not possible |
|
Dual 10 Gigabit Ethernet card | SE1X7HE3G | 2CPU:3 (#0,#3,#7) 4CPU:6 (#0,#1,#3,#5,#7,#9) |
2CPU:2 (#0,#3,#7) 4CPU:5 (#0,#1,#3,#5,#7,#9) PCI expansion unit mounting not possible |
|
Quad 10 Gigabit Ethernet card | SP1X7HH1F | - | - | |
Dual 40 Gigabit Ethernet card | SP1X7HG1F | - | - | |
FCoE | Dual 10Gbps FCoE card (for optical cable) | SE0X7EF12F | 2CPU:3 (#0,#3,#7) 4CPU:6 (#0,#1,#3,#5,#7,#9) |
2CPU:2 (#0,#3,#7) 4CPU:5 (#0,#1,#3,#5,#7,#9) PCI expansion unit mounting not possible |
Dual 10Gbps FCoE card (for Copper Twinax cable) | SE0X7EC12F | 2CPU:3 (#0,#3,#7) 4CPU:6 (#0,#1,#3,#5,#7,#9) |
2CPU:2 (#0,#3,#7) 4CPU:5 (#0,#1,#3,#5,#7,#9) PCI expansion unit mounting not possible |
|
Dual-channel 10Gbps FCoE card (for optical cable) (QLogic) | SP1X7FAR2F | 2CPU:3 (#0,#3,#7) 4CPU:6 (#0,#1,#3,#5,#7,#9) |
2CPU:2 (#0,#3,#7) 4CPU:5 (#0,#1,#3,#5,#7,#9) PCI expansion unit mounting not possible |
|
Dual-channel 10Gbps FCoE card (for Copper Twinax cable) (QLogic) | SP1X7FAS2F | 2CPU:3 (#0,#3,#7) 4CPU:6 (#0,#1,#3,#5,#7,#9) |
2CPU:2 (#0,#3,#7) 4CPU:5 (#0,#1,#3,#5,#7,#9) PCI expansion unit mounting not possible |
|
Dual-channel 10Gbps FCoE card (for optical cable) (Emulex) | SP1X7FBR2F | 2CPU:3 (#0,#3,#7) 4CPU:6 (#0,#1,#3,#5,#7,#9) |
2CPU:2 (#0,#3,#7) 4CPU:5 (#0,#1,#3,#5,#7,#9) PCI expansion unit mounting not possible |
|
Dual-channel 10Gbps FCoE card (for Copper Twinax cable) (Emulex) | SP1X7FBS2F | 2CPU:3 (#0,#3,#7) 4CPU:6 (#0,#1,#3,#5,#7,#9) |
2CPU:2 (#0,#3,#7) 4CPU:5 (#0,#1,#3,#5,#7,#9) PCI expansion unit mounting not possible |
|
FC | Dual-channel 32 Gbps Fibre Channel card | SP1X7FAC2F | - | - |
Dual-channel 32 Gbps Fibre Channel card | SP1X7FBC2F | - | - | |
Dual-channel 16Gbps Fibre Channel card (SR SFP+) | SP1X7FAA2F | 11 | 2CPU:41 4CPU:71 |
|
Dual-channel 16Gbps Fibre Channel card (LR SFP+) | SP1X7FAB2F | 11 | 2CPU:41 4CPU:71 |
|
Dual-channel 16Gbps Fibre Channel card (SR SFP+) | SP1X7FBA2F | 2CPU:3 (#0,#3,#7) 4CPU:6 (#0,#1,#3,#5,#7,#9) |
2CPU:2 (#0,#3,#7) 4CPU:5 (#0,#1,#3,#5,#7,#9) PCI expansion unit mounting not possible |
|
Quad-channel 16Gbps Fibre Channel card (SR) | SP0X7FAA4F | - | - | |
Dual-channel 8Gbps Fibre Channel card (QLogic) | SE0X7F22F | 11 | 2CPU:41 4CPU:71 |
|
Single-channel 8Gbps Fibre Channel card (QLogic) | SE0X7F21F | 11 | 2CPU:41 4CPU:71 |
|
Dual-channel 8Gbps Fibre Channel card (Emulex) | SE0X7F32F | 2CPU:3 (#0,#3,#7) 4CPU:6 (#0,#1,#3,#5,#7,#9) |
2CPU:2 (#0,#3,#7) 4CPU:5 (#0,#1,#3,#5,#7,#9) PCI expansion unit mounting not possible |
|
Single-channel 8Gbps Fibre Channel card (Emulex) | SE0X7F31F | 2CPU:3 (#0,#3,#7) 4CPU:6 (#0,#1,#3,#5,#7,#9) |
2CPU:2 (#0,#3,#7) 4CPU:5 (#0,#1,#3,#5,#7,#9) PCI expansion unit mounting not possible |
|
SAS | 12Gbps SAS card (*1) | SP1X7SA3F | 11 | 2CPU:41 4CPU:71 |
6Gbps SAS card | SE0X7SA2F | 11 | 2CPU:41 4CPU:71 |
|
SAS card | SE0X7SA1F | 11 | 2CPU:41 4CPU:71 |
|
FLASH | 3.2 TB Flash Accelerator Card | SP0X7Y42F | - | - |
Flash Accelerator F320 card | SP1X7Y41F | - | - | |
Flash Accelerator F160 card | SP1X7Y31F | - | - | |
Flash Accelerator F80 card | SP1X7Y21F | 11 | 2CPU:41 4CPU:71 |
|
Flash Accelerator F40 card | SP1X7Y11F | 11 | 2CPU:41 4CPU:71 |
|
IB | Dual Port InfiniBand 4x QDR card | SP1X7BA12F | 2CPU:3 (#0,#3,#7) (*2) 4CPU:6 (#0,#1,#3,#5,#7,#9) |
2CPU:2 (#0,#3,#7) (*2) 4CPU:5 (#0,#1,#3,#5,#7,#9) PCI expansion unit mounting not possible |
Dual Port InfiniBand 4x QDR card | SE1X7BA12F | 11 | 2CPU:41 4CPU:71 |
|
Graphic | Graphics card (*3) | SP0X7GR1F | 1 (#1,#2) |
1 (#1,#2) PCI expansion unit mounting not possible |
-: Not applicable *1 To use the 12Gbps SAS card, the following SRU must be applied: SRU 11.2.8.4.0 or later *2 If this card is mounted in Slot#0 in a 2-CPU configuration, Slot#2 cannot be used. If this card is mounted in Slot#3, Slot#5 and #6 cannot be used. If this card is mounted in Slot#7, Slot#9 and #10 cannot be used. *3 The supplied software installation CD-ROM is not supported in the Oracle Solaris 11.4 environment. To use this in the Oracle Solaris 11.4 environment, you need to purchase the FUJITSU Software graphics card driver (order name: B23S0Y180). |
Type | Product Name | Factory-Mounted Product ID When Shipped | Maximum Number Mounted | ||
---|---|---|---|---|---|
(Expanded-on-Site Product ID) | Without PCI Expansion Unit | With PCI Expansion Unit | |||
Link | Link card kit | 7105513 (7105576) | - | 2CPU:3 (#0,#3,#7) 4CPU:6 (#0,#1,#3,#5,#7,#9) |
|
LAN | Sun Dual Port GbE PCIe 2.0 Low Profile Adapter, MMF | 7100482 (7100481) | 11 | 2CPU:41 4CPU:71 |
|
Sun Quad Port GbE PCIe 2.0 Low Profile Adapter, UTP | 7100479 (7100477) | 11 | 2CPU:41 4CPU:71 |
||
Sun Dual Port 10GBase-T Adapter | 7100563 (7100488) | 2CPU:3 (#0,#3,#7) 4CPU:6 (#0,#1,#3,#5,#7,#9) |
2CPU:2 (#0,#3,#7) 4CPU:5 (#0,#1,#3,#5,#7,#9) PCI expansion unit mounting not possible |
||
Sun Dual 10 GbE SFP+ PCIe 2.0 Low Profile Adapter | 1109A-Z (X1109A-Z) | 2CPU:3 (#0,#3,#7) 4CPU:6 (#0,#1,#3,#5,#7,#9) |
2CPU:2 (#0,#3,#7) 4CPU:5 (#0,#1,#3,#5,#7,#9) PCI expansion unit mounting not possible |
||
Oracle Quad Port 10GBase-T Adapter | 7111182 (7111181) | - | - | ||
Oracle Quad 10 Gb or Dual 40 Gb Ethernet Adapter | 7114148 (7114134) | - | - | ||
PCIe Quad port GigE (copper) x8 lane card | 4447A-Z-N (X4447A- Z-N) |
2CPU:3 (#0,#3,#7) 4CPU:6 (#0,#1,#3,#5,#7,#9) |
2CPU:2 (#0,#3,#7) 4CPU:5 (#0,#1,#3,#5,#7,#9) PCI expansion unit mounting not possible |
||
PCI-E Low-Profile Dual GigE MMF | 7281A-2-N (X7281A- 2-N) |
2CPU:3 (#0,#3,#7) 4CPU:6 (#0,#1,#3,#5,#7,#9) |
2CPU:2 (#0,#3,#7) 4CPU:5 (#0,#1,#3,#5,#7,#9) PCI expansion unit mounting not possible |
||
FC/FCoE | Oracle Storage Dual-Port 32 Gb Fibre Channel PCIe Low Profile HBA, QLogic | 7115460 (7115462) | - | - | |
Oracle Storage Dual-Port 32 Gb Fibre Channel PCIe Low Profile HBA, Emulex | 7115459 (7115461) | - | - | ||
Sun Storage 10 GbE PCIe FCoE Converged Network Adapter: QLogic low profile, dual port and SR optics | SG-PCIEFCOE2-Q- SR (7105381, SG- XPCIEFCOE2-Q-SR) |
2CPU:3 (#0,#3,#7) 4CPU:6 (#0,#1,#3,#5,#7,#9) |
2CPU:2 (#0,#3,#7) 4CPU:5 (#0,#1,#3,#5,#7,#9) PCI expansion unit mounting not possible |
||
Sun Storage 10 GbE PCIe FCoE Converged Network Adapter: QLogic low profile, dual port and Twin-AX | SG-PCIEFCOE2-Q- TA (7105382, SG- XPCIEFCOE2-Q-TA) |
2CPU:3 (#0,#3,#7) 4CPU:6 (#0,#1,#3,#5,#7,#9) |
2CPU:2 (#0,#3,#7) 4CPU:5 (#0,#1,#3,#5,#7,#9) PCI expansion unit mounting not possible |
||
Sun Storage 16 Gb Fibre Channel PCIe Universal Host Bus Adapter, Qlogic | 7101673 (7101674) | - | - | ||
with the 16 Gb FC short wave optics | with 7101675 (7101676) | 11 | 2CPU:41 4CPU:71 |
||
with the 16 Gb FC long wave optics | with 7101679 (7101680) | 11 | 2CPU:41 4CPU:71 |
||
with the 10 Gb FCoE short reach optics or TwinAx cables | with 7101677 (7101678) or TwinAx cables |
2CPU:3 (#0,#3,#7) 4CPU:6 (#0,#1,#3,#5,#7,#9) |
2CPU:2 (#0,#3,#7) 4CPU:5 (#0,#1,#3,#5,#7,#9) PCI expansion unit mounting not possible |
||
Sun Storage 16 Gb Fibre Channel PCIe Universal Host Bus Adapter, Emulex | 7101683 (7101684) | - | - | ||
with the 16 Gb FC short wave optics | with 7101685 (7101686) | 2CPU:3 (#0,#3,#7) 4CPU:6 (#0,#1,#3,#5,#7,#9) |
2CPU:2 (#0,#3,#7) 4CPU:5 (#0,#1,#3,#5,#7,#9) PCI expansion unit mounting not possible |
||
with the 10 Gb FCoE short reach optics or TwinAx cables | with 7101687 (7101688) | 2CPU:3 (#0,#3,#7) 4CPU:6 (#0,#1,#3,#5,#7,#9) |
2CPU:2 (#0,#3,#7) 4CPU:5 (#0,#1,#3,#5,#7,#9) PCI expansion unit mounting not possible |
||
8 Gb FC PCIe, QLogic, Dual Port |
SG-PCIE2FC-QF8-Z (SG-XPCIE2FC-QF8- N) |
11 | 2CPU:41 4CPU:71 |
||
8 Gb FC PCIe, QLogic, Single Port |
SG-PCIE1FC-QF8-Z (SG-XPCIE1FC-QF8- N) |
11 | 2CPU:41 4CPU:71 |
||
8 Gb FC PCIe, Emulex, Dual Port |
SG-PCIE2FC-EM8- Z (SG-XPCIE2FC- EM8-N) |
2CPU:3 (#0,#3,#7) 4CPU:6 (#0,#1,#3,#5,#7,#9) |
2CPU:2 (#0,#3,#7) 4CPU:5 (#0,#1,#3,#5,#7,#9) PCI expansion unit mounting not possible |
||
8 Gb FC PCIe, Emulex, Single Port |
SG-PCIE1FC-EM8- Z (SG-XPCIE1FC- EM8-N) |
2CPU:3 (#0,#3,#7) 4CPU:6 (#0,#1,#3,#5,#7,#9) |
2CPU:2 (#0,#3,#7) 4CPU:5 (#0,#1,#3,#5,#7,#9) PCI expansion unit mounting not possible |
||
SAS | Oracle Storage 12 Gb SAS PCIe HBA, external: 8 port (*1) | 7110118 (7110119) | 11 | 2CPU:41 4CPU:71 |
|
Sun Storage 6 Gb SAS PCIe HBA: 8 ports, external | SG-SAS6-EXT-Z (7105387, SGX-SAS6- EXT-Z) |
11 | 2CPU:41 4CPU:71 |
||
Sun StorageTek 8-port External SAS PCI-Express Host Bus Adapter | SG-PCIE8SAS-E-Z- N (SG-XPCIE8SAS- E-Z-N) |
11 | 2CPU:41 4CPU:71 |
||
FLASH | Fujitsu 3.2 TB Flash Accelerator Card | 7119601 (7119603) | - | - | |
Oracle Flash Accelerator F320 PCIe Card | 7113825 (7113826) | - | - | ||
Flash Accelerator F160 PCIe Card | 7110864 (7110865) | - | - | ||
Flash Accelerator F80 PCIe Card: 800GB, eMLC | 7107091 (7107092) | 11 | 2CPU:41 4CPU:71 |
||
Flash Accelerator F40 card | 7104480 (7104482) | 11 | 2CPU:41 4CPU:71 |
||
IB | Oracle Dual port QDR InfiniBand Adapter M3 | 7104073 (7104074) | 2CPU:3 (#0,#3,#7) (*2) 4CPU:6 (#0,#1,#3,#5,#7,#9) |
2CPU:2 (#0,#3,#7) (*2) 4CPU:5 (#0,#1,#3,#5,#7,#9) PCI expansion unit mounting not possible |
|
Sun InfiniBand QDR Host Channel Adapter PCIe: low profile | 4242A (X4242A) | 11 | 2CPU:41 4CPU:71 |
||
Graphic | Raptor GFX 550e (*3) | - | 1 (#1,#2) |
1 (#1,#2) PCI expansion unit mounting not possible |
|
-: Not applicable *1 To use the 12Gbps SAS card, the following SRU and card FW must be applied: SRU 11.2.8.4.0 or later, card FW: 06.00.00.00 or later *2 If this card is mounted in Slot#0 in a 2-CPU configuration, Slot#2 cannot be used. If this card is mounted in Slot#3, Slot#5 and #6 cannot be used. If this card is mounted in Slot#7, Slot#9 and #10 cannot be used. *3 Sales Contact EIZO Rugged Solutions, Inc.: ers-info@eizo.com Shoshin Corporation: isï¼ shoshin.co.jp |