Table 2-1  Maximum Number of Each Type of Mounted PCI Card: SPARC M10-4 With Oracle Solaris 11 (Fujitsu Product ID)
Type Product Name Product ID Maximum Number Mounted
Without PCI Expansion Unit With PCI Expansion Unit
Link PCI expansion unit connection card SPME8LK1F - 2CPU:3 (#0,#3,#7)
4CPU:6 (#0,#1,#3,#5,#7,#9)
LAN Dual Gigabit Ethernet card (MMF) SP1X7GD2F 11 2CPU:41
4CPU:71
  Dual Gigabit Ethernet card (MMF) SP1X7GD1F 11 2CPU:41
4CPU:71
  Quad Gigabit Ethernet card (UTP) SP1X7GQ2F 11 2CPU:41
4CPU:71
  Quad Gigabit Ethernet card (UTP) SP1X7GQ1F 11 2CPU:41
4CPU:71
  Dual 10Gigabit Ethernet card
(10GBase-T)
SP1X7HF1F 11 2CPU:41
4CPU:71
  Dual 10Gigabit Ethernet card SE1X7HE3G 11 2CPU:41
4CPU:71
  Quad 10 Gigabit Ethernet card (*1) SP1X7HH1F 5 2CPU:20 (*2)
4CPU:35 (*2)
  Dual 40 Gigabit Ethernet card (*3) SP1X7HG1F 11 2CPU:41
4CPU:71
FCoE Dual 10Gbps FCoE card (for optical cable) SE0X7EF12F 11 2CPU:41
4CPU:71
  Dual 10Gbps FCoE card (for Copper Twinax cable) SE0X7EC12F 11 2CPU:41
4CPU:71
  Dual-channel 10Gbps FCoE card (for optical cable) (QLogic) SP1X7FAR2F 11 2CPU:41
4CPU:71
  Dual-channel 10Gbps FCoE card (for Copper Twinax cable) (QLogic) SP1X7FAS2F 11 2CPU:41
4CPU:71
  Dual-channel 10Gbps FCoE card (for optical cable) (Emulex) SP1X7FBR2F 11 2CPU:41
4CPU:71
  Dual-channel 10Gbps FCoE card (for Copper Twinax cable) (Emulex) SP1X7FBS2F 11 2CPU:41
4CPU:71
FC Dual-channel 32Gbps Fibre Channel card (*4) SP1X7FAC2F 11 2CPU:41
4CPU:71
  Dual-channel 32Gbps Fibre Channel card (*5) SP1X7FBC2F 11 2CPU:41
4CPU:71
  Dual-channel 16Gbps Fibre Channel card (SR SFP+) SP1X7FAA2F 11 2CPU:41
4CPU:71
  Dual-channel 16Gbps Fibre Channel card (LR SFP+) SP1X7FAB2F 11 2CPU:41
4CPU:71
  Dual-channel 16Gbps Fibre Channel card (SR SFP+) SP1X7FBA2F 11 2CPU:41
4CPU:71
  Quad-channel 16Gbps Fibre Channel card (SR) (*6) SP0X7FAA4F 11 2CPU:41
4CPU:71
  Dual-channel 8Gbps Fibre Channel card (QLogic) SE0X7F22F 11 2CPU:41
4CPU:71
  Single-channel 8Gbps Fibre Channel card (QLogic) SE0X7F21F 11 2CPU:41
4CPU:71
  Dual-channel 8Gbps Fibre Channel card (Emulex) SE0X7F32F 11 2CPU:41
4CPU:71
  Single-channel 8Gbps Fibre Channel card (Emulex) SE0X7F31F 11 2CPU:41
4CPU:71
SAS 12Gbps SAS card (*7) SP1X7SA3F 11 2CPU:41
4CPU:71
  6Gbps SAS card SE0X7SA2F 11 2CPU:41
4CPU:71
  SAS card SE0X7SA1F 11 2CPU:41
4CPU:71
FLASH 3.2 TB Flash Accelerator Card (*8) SP0X7Y42F 11 2CPU:41
4CPU:71
  Flash Accelerator F320 card (*9) SP1X7Y41F 11 2CPU:41
4CPU:71
  Flash Accelerator F160 card (*10) SP1X7Y31F 11 2CPU:41
4CPU:71
  Flash Accelerator F80 card SP1X7Y21F 11 2CPU:41
4CPU:71
  Flash Accelerator F40 card SP1X7Y11F 11 2CPU:41
4CPU:71
IB Dual Port InfiniBand 4x QDR card SP1X7BA12F 2CPU:3 (#0,#3,#7) (*11)
4CPU:6 (#0,#1,#3,#5,#7,#9)
2CPU:2 (#0,#3,#7) (*11)
4CPU:5 (#0,#1,#3,#5,#7,#9)
PCI expansion unit mounting not possible
  Dual Port InfiniBand 4x QDR card SE1X7BA12F 11 2CPU:41
4CPU:71
Graphic Graphics card (*12) SP0X7GR1F
1 (#1,#2)
1 (#1,#2)

PCI expansion unit mounting not possible
-: Not applicable

*1 To use the Quad 10 Gigabit Ethernet card, the following SRU and XCP must be applied:
SRU 11.3.22.3.0 or later, XCP 2320 or later
To mount the Quad 10 Gigabit Ethernet card in the PCI expansion unit, PCI expansion unit firmware version 1310 or later must be applied in addition to the above.
For details on the application of the PCI expansion unit firmware, see the PCI Expansion Unit for Fujitsu M10/SPARC M10 Systems Service Manual.
*2 Up to five Quad 10 Gigabit Ethernet cards can be mounted per PCI expansion unit.
*3 To use the 40 Gb Ethernet card, the following SRU and XCP must be applied:
SRU 11.3.8.7.0 or later, XCP 2320 or later
To mount the 40Gb Ethernet card in the PCI expansion unit, PCI expansion unit firmware version 1310 or later must be applied in addition to the above. For details on the application of the PCI expansion unit firmware, see the PCI Expansion Unit for Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Service Manual.
*4 To use the dual-channel 32Gbps Fibre Channel card, the following SRU must be applied:
SRU 11.3.29.5.0 or later
*5 To use the dual-channel 32Gbps Fibre Channel card, the following SRU must be applied:
SRU 11.3.23.5.0 or later
*6 To use the quad-channel 16Gbps Fibre Channel card, the following SRU must be applied:
SRU 11.3.29.5.0 or later
*7 To use the 12Gbps SAS card, the following SRU must be applied:
SRU 11.2.8.4.0 or later
*8 To use the 3.2 TB Flash Accelerator Card, the following SRU and XCP must be applied:
SRU 11.3.28.4.0 or later, XCP 2320 or later
*9 To use the F320 card, the following SRU and XCP must be applied:
SRU 11.3.10.7.0 or later, XCP 2320 or later
*10 To use the F160 card, the following SRU and XCP must be applied:
SRU 11.2.11.5.0 or later, XCP 2260 or later
To mount the F160 card in the PCI expansion unit, PCI expansion unit firmware version 1210 or later must be applied in addition to the above.
For details on the application of the PCI expansion unit firmware, see the PCI Expansion Unit for Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Service Manual.
In addition, when the PCI expansion unit is to be assigned to a Guest domain while Direct I/O for the PCI expansion unit is unused, perform static allocation and set nvramrc.
{0} ok nvedit
0: d# 10000 ms
{0} ok nvstore
{0} ok setenv use-nvramrc? true
This setting is unnecessary when XCP 2290 or later is to be applied.
*11 If this card is mounted in Slot#0 in a 2-CPU configuration, Slot#2 cannot be used. If this card is mounted in Slot#3, Slot#5 and #6 cannot be used. If this card is mounted in Slot#7, Slot#9 and #10 cannot be used.
*12 The supplied software installation CD-ROM is not supported in the Oracle Solaris 11.4 environment.
To use this in the Oracle Solaris 11.4 environment, you need to purchase the FUJITSU Software graphics card driver (order name: B23S0Y180).
Table 2-2  Maximum Number of Each Type of Mounted PCI Card: SPARC M10-4 With Oracle Solaris 11 (Oracle Product ID)
Type Product Name Factory-Mounted Product ID When Shipped Maximum Number Mounted
(Expanded-on-Site Product ID) Without PCI Expansion Unit With PCI Expansion Unit
Link Link card kit 7105513 (7105576) - 2CPU:3 (#0,#3,#7)
4CPU:6 (#0,#1,#3,#5,#7,#9)
LAN Sun Dual Port GbE PCIe 2.0 Low Profile Adapter, MMF 7100482 (7100481) 11 2CPU:41
4CPU:71
  Sun Quad Port GbE PCIe 2.0 Low Profile Adapter, UTP 7100479 (7100477) 11 2CPU:41
4CPU:71
  Sun Dual Port 10GBase-T Adapter 7100563 (7100488) 11 2CPU:41
4CPU:71
  Sun Dual 10 GbE SFP+ PCIe 2.0 Low Profile Adapter 1109A-Z (X1109A-Z) 11 2CPU:41
4CPU:71
  Oracle Quad Port 10GBase-T Adapter (*1) 7111182 (7111181) 5 2CPU:20 (*2)
4CPU:35 (*2)
  Oracle Quad 10 Gb or Dual 40 Gb Ethernet Adapter (*3) 7114148 (7114134) 11 2CPU:41
4CPU:71
  PCIe Quad port GigE (copper) x8 lane card 4447A-Z-N (X4447A-
Z-N)
11 2CPU:41
4CPU:71
  PCI-E Low-Profile Dual GigE MMF 7281A-2-N (X7281A-
2-N)
11 2CPU:41
4CPU:71
FC/FCoE Oracle Storage Dual-Port 32 Gb Fibre Channel PCIe Low Profile HBA, QLogic (*4) 7115460 (7115462) 11 2CPU:41
4CPU:71
  Oracle Storage Dual-Port 32 Gb Fibre Channel PCIe Low Profile HBA, Emulex (*5) 7115459 (7115461) 11 2CPU:41
4CPU:71
  Sun Storage 10 GbE PCIe FCoE Converged Network Adapter: QLogic low profile, dual port and SR optics SG-PCIEFCOE2-Q-
SR (7105381, SG-
XPCIEFCOE2-Q-SR)
11 2CPU:41
4CPU:71
  Sun Storage 10 GbE PCIe FCoE Converged Network Adapter: QLogic low profile, dual port and Twin-AX SG-PCIEFCOE2-Q-
TA (7105382, SG-
XPCIEFCOE2-Q-TA)
11 2CPU:41
4CPU:71
  Sun Storage 16 Gb Fibre Channel PCIe Universal Host Bus Adapter, Qlogic 7101673 (7101674) - -
    with the 16 Gb FC short wave optics with 7101675 (7101676) 11 2CPU:41
4CPU:71
    with the 16 Gb FC long wave optics with 7101679 (7101680) 11 2CPU:41
4CPU:71
    with the 10 Gb FCoE short reach optics or TwinAx cables with 7101677 (7101678)
or TwinAx cables
11 2CPU:41
4CPU:71
  Sun Storage 16 Gb Fibre Channel PCIe Universal Host Bus Adapter, Emulex 7101683 (7101684) - -
    with the 16 Gb FC short wave optics with 7101685 (7101686) 11 2CPU:41
4CPU:71
    with the 10 Gb FCoE short reach optics or TwinAx cables with 7101687 (7101688) 11 2CPU:41
4CPU:71
 
8 Gb FC PCIe, QLogic, Dual Port
SG-PCIE2FC-QF8-Z
(SG-XPCIE2FC-QF8-
N)
11 2CPU:41
4CPU:71
 
8 Gb FC PCIe, QLogic, Single Port
SG-PCIE1FC-QF8-Z
(SG-XPCIE1FC-QF8-
N)
11 2CPU:41
4CPU:71
 
8 Gb FC PCIe, Emulex, Dual Port
SG-PCIE2FC-EM8-
Z (SG-XPCIE2FC-
EM8-N)
11 2CPU:41
4CPU:71
 
8 Gb FC PCIe, Emulex, Single Port
SG-PCIE1FC-EM8-
Z (SG-XPCIE1FC-
EM8-N)
11 2CPU:41
4CPU:71
SAS Oracle Storage 12 Gb SAS PCIe HBA, external: 8 port (*6) 7110118 (7110119) 11 2CPU:41
4CPU:71
  Sun Storage 6 Gb SAS PCIe HBA: 8 ports, external SG-SAS6-EXT-Z
(7105387, SGX-SAS6-
EXT-Z)
11 2CPU:41
4CPU:71
  Sun StorageTek 8-port External SAS PCI-Express Host Bus Adapter SG-PCIE8SAS-E-Z-
N (SG-XPCIE8SAS-
E-Z-N)
11 2CPU:41
4CPU:71
FLASH Fujitsu 3.2 TB Flash Accelerator Card (*7) 7119601 (7119603) 11 2CPU:41
4CPU:71
  Oracle Flash Accelerator F320 PCIe Card (*8) 7113825 (7113826) 11 2CPU:41
4CPU:71
  Flash Accelerator F160 PCIe Card (*9) 7110864 (7110865) 11 2CPU:41
4CPU:71
  Flash Accelerator F80 PCIe Card: 800GB, eMLC 7107091 (7107092) 11 2CPU:41
4CPU:71
  Flash Accelerator F40 card 7104480 (7104482) 11 2CPU:41
4CPU:71
IB Oracle Dual port QDR InfiniBand Adapter M3 7104073 (7104074) 2CPU:3 (#0,#3,#7) (*10)
4CPU:6 (#0,#1,#3,#5,#7,#9)
2CPU:2 (#0,#3,#7) (*10)
4CPU:5 (#0,#1,#3,#5,#7,#9)
PCI expansion unit mounting not possible
  Sun InfiniBand QDR Host Channel Adapter PCIe: low profile 4242A (X4242A) 11 2CPU:41
4CPU:71
Graphic Raptor GFX 550e (*11) -
1 (#1,#2)
1 (#1,#2)

PCI expansion unit mounting not possible
-: Not applicable

*1 To use the Oracle Quad Port 10GBase-T Adapter, the following SRU and XCP must be applied:
SRU 11.3.22.3.0 or later, XCP 2320 or later
To mount the Oracle Quad Port 10GBase-T Adapter in the PCI expansion unit, PCI expansion unit firmware version 1310 or later must be applied in addition to the above.
For details on the application of the PCI expansion unit firmware, see the PCI Expansion Unit for Fujitsu M10/SPARC M10 Systems Service Manual.
*2 Up to five Oracle Quad Port 10GBase-T Adapters can be mounted per PCI expansion unit.
*3 To use the 40 Gb Ethernet card, the following SRU and XCP must be applied:
SRU 11.3.8.7.0 or later, XCP 2320 or later
To mount the 40Gb Ethernet card in the PCI expansion unit, PCI expansion unit firmware version 1310 or later must be applied in addition to the above. For details on the application of the PCI expansion unit firmware, see the PCI Expansion Unit for Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Service Manual.
*4 To use the Oracle Storage Dual-Port 32 Gb Fibre Channel PCIe Low Profile HBA, QLogic, the following SRU must be applied:
SRU 11.3.29.5.0 or later
*5 To use the Oracle Storage Dual-Port 32 Gb Fibre Channel PCIe Low Profile HBA, Emulex, the following SRU must be applied:
SRU 11.3.23.5.0 or later
*6 To use the 12Gbps SAS card, the following SRU and card FW must be applied:
SRU 11.2.8.4.0 or later, card FW: 06.00.00.00 or later
*7 To use the Fujitsu 3.2 TB Flash Accelerator Card, the following SRU and XCP must be applied:
SRU 11.3.28.4.0 or later, XCP 2320 or later
*8 To use the F320 card, the following SRU and XCP must be applied:
SRU 11.3.10.7.0 or later, XCP 2320 or later
*9 To use the F160 card, the following SRU and XCP must be applied:
SRU 11.2.14.4.0 or later, XCP 2260 or later
To mount the F160 card in the PCI expansion unit, PCI expansion unit firmware version 1210 or later must be applied in addition to the above.
For details on the application of the PCI expansion unit firmware, see the PCI Expansion Unit for Fujitsu SPARC M12 and Fujitsu M10/SPARC M10 Service Manual.
In addition, when the PCI expansion unit is to be assigned to a Guest domain while Direct I/O for the PCI expansion unit is unused, perform static allocation and set nvramrc.
{0} ok nvedit
0: d# 10000 ms
{0} ok nvstore
{0} ok setenv use-nvramrc? true
This setting is unnecessary when XCP 2290 or later is to be applied.
*10 If this card is mounted in Slot#0 in a 2-CPU configuration, Slot#2 cannot be used. If this card is mounted in Slot#3, Slot#5 and #6 cannot be used.
If this card is mounted in Slot#7, Slot#9 and #10 cannot be used.
*11 Sales Contact
EIZO Rugged Solutions, Inc.: ers-info@eizo.com
Shoshin Corporation: isï¼ shoshin.co.jp