2.9.1 Electrical specifications


2.9.1 Electrical specifications
Table 2-8 and Table 2-9 list the electrical specifications of each chassis.
Note - The values listed in Table 2-8 and Table 2-9 are based on values for the maximum configuration of each chassis. The actual values vary depending on the system configuration.
Table 2-8  Electrical specifications (SPARC M10-1)
Item Specification  
  Input voltage of 100 to 120 VAC Input voltage of 200 to 240 VAC
  CPU type:
SPARC64 X
CPU type:
SPARC64 X+
CPU type:
SPARC64 X
CPU type:
SPARC64 X+
Number of power cords 2
(1 for each PSU)
2
(1 for each PSU)
Power cord length (*1) Maximum length of 3.0 m (9.8 ft.) Maximum length of 3.0 m (9.8 ft.)
Redundancy 1+1 redundant configuration   1+1 redundant configuration  
Frequency
50 Hz/60 Hz, single phase
 
50 Hz/60 Hz, single phase
 
Maximum input current (*2) 8.2 A 8.7 A 4.0 A 4.2 A
Maximum power consumption 806 W 849 W 783 W 824 W
Apparent power
822 VA
866 VA
807 VA
849 VA
Rush current (*3)
40 A peak or less
40 A peak or less
Leakage current (*3) 1.75 mA or less 1.75 mA or less
*1 The SPARC M10-1 is pulled out to perform maintenance. Therefore, you need to consider an extra length of 1.5 m when ordering the power cord.
*2 The current that flows through each power cord in a redundant configuration is half the value listed in Table 2-8.
*3 The value is per power cord.
 
Table 2-9  Electrical specifications (PCI expansion unit)
Item Specification
  Input voltage of 100 to 120 VAC Input voltage of 200 to 240 VAC
Number of power cords
2 (1 for each PSU)
2 (1 for each PSU)
Power cord length Maximum length of 3.0 m (9.8 ft.) Maximum length of 3.0 m (9.8 ft.)
Redundancy 1+1 redundant configuration 1+1 redundant configuration
Frequency
50 Hz/60 Hz, single phase
50 Hz/60 Hz, single phase
Maximum input current (*1) 2.9 A 1.4 A
Maximum power consumption 279 W 270 W
Apparent power
284 VA
276 VA
Rush current (*2)
40 A peak or less
40 A peak or less
Leakage current (*2) 1.75 mA or less 1.75 mA or less
*1 The current that flows through each power cord in a redundant configuration is half the value listed in Table 2-9.
*2 The value is per power cord.