Appendix B Cards That Support PCI Hot Plug and Dynamic Reconfiguration
Appendix B Cards That Support PCI Hot Plug and Dynamic Reconfiguration
This appendix describes cards that support PCI Hot Plug and dynamic reconfiguration.
The SPARC M12 on-board PCI slots and the PCI expansion unit support active replacement and active addition of PCI cards using PCI Hot Plug (PHP).
The SPARC M12 supports the physical partition dynamic reconfiguration (DR) function. If a card that does not support the dynamic reconfiguration (DR) function is mounted in a physical partition, the physical partition cannot be dynamically reconfigured. In that case, perform replacement or maintenance in the inactive state.
Table B-1 lists the PHP/DR supporting cards that have Fujitsu product IDs. Table B-2 lists the PHP/DR supporting cards that have Oracle product IDs.
The SPARC M12 on-board PCI slots and the PCI expansion unit support active replacement and active addition of PCI cards using PCI Hot Plug (PHP).
The SPARC M12 supports the physical partition dynamic reconfiguration (DR) function. If a card that does not support the dynamic reconfiguration (DR) function is mounted in a physical partition, the physical partition cannot be dynamically reconfigured. In that case, perform replacement or maintenance in the inactive state.
Table B-1 lists the PHP/DR supporting cards that have Fujitsu product IDs. Table B-2 lists the PHP/DR supporting cards that have Oracle product IDs.
Category | Name | Product ID | Driver Name Software Product Name |
PHP: PCI Hot Plug | DR: Dynamic Reconfiguration | Path Redundancy Software |
|||
---|---|---|---|---|---|---|---|---|---|
Active Replacement | Active Addition | Active Replacement | Active Addition | Suspend/Resume Processing Time (*1) | |||||
Link | PCI expansion unit connection card | SPME8LK1F | None | Supported | Supported (*2) | Supported | Supported | 0.1 sec. (*3) | None |
LAN | Dual Gigabit Ethernet card (MMF) | SP1X7GD2F | igb | Supported | Supported | To be supported | Oracle Solaris standard multi-path function (IPMP), or PRIMECLUSTER GLS 4.3A20 or later | ||
Quad Gigabit Ethernet card (UTP) | SP1X7GQ2F | igb | Supported | Supported | Supported | Supported | 0.8 sec. | ||
Dual 10 Gigabit Ethernet card | SE1X7HE3G | ixgbe | Supported | Supported | Supported (*4) | Supported (*4) | 0.4 sec. | ||
Dual 10 Gigabit Ethernet card (10GBase-T) | SP1X7HF1F | ixgbe | Supported | Supported | Supported (*4) | Supported (*4) | 0.4 sec. | ||
Quad 10 Gigabit Ethernet card | SP1X7HH1F | i40e | Supported | Not supported | Supported (*4) | Supported (*4) | 1.0 sec. | ||
Dual 25 Gigabit Ethernet card | SP1X7JD1F | bnxt | Not supported | Not supported | Supported (*5) | Supported | 0.1 sec. | ||
Dual 40 Gigabit Ethernet card | SP1X7HG1F | i40e | Supported (*6) | Not supported | Supported (*6) | Supported (*6) | 1.5 sec. | ||
FCoE | Dual-Channel 10 Gbps FCoE card (for optical cable) | SP1X7FAR2F | qlc, qlcnic | Not supported | Not supported | Supported (*7) | Supported (*7) | 20 sec. (*8) |
Network redundancy: Oracle Solaris standard multi-path function (IPMP) FC redundancy: Oracle Solaris standard multi-path function (mpxio) or ETERNUS multi-path driver 3.1.0 or later |
Dual-Channel 10 Gbps FCoE card (for Copper Twinax cable) | SP1X7FAS2F | qlc, qlcnic | Not supported | Not supported | Supported (*7) | Supported (*7) | 20 sec. (*8) |
||
FC | Dual-Channel 32 Gbps Fibre Channel card | SP1X7FAC2F | qlc | Supported | Supported | Not supported | Not supported | - | |
Dual-Channel 32 Gbps Fibre Channel card | SP1X7FBC2F | emlxs | Supported | Supported | Supported | Supported | 37 sec. (*9) |
||
Dual-Channel 16 Gbps Fibre Channel card (SR SFP+) | SP1X7FAA2F | qlc | Supported | Supported (*10) | Supported | Supported | 20 sec. (*8) |
Oracle Solaris standard multi-path function (mpxio) or ETERNUS multi-path driver 3.1.0 or later | |
Dual-Channel 16 Gbps Fibre Channel card (LR SFP+) | SP1X7FAB2F | qlc | Supported | Supported (*10) | Supported | Supported | 20 sec. (*8) |
||
Dual-Channel 16 Gbps Fibre Channel card (SR SFP+) | SP1X7FBA2F | emlxs | Supported | Supported | Supported | Supported | 37 sec. (*9) |
||
Quad-Channel 16 Gbps Fibre Channel card (SR) | SP0X7FAA4F | qlc | Supported | Supported | Not supported | Not supported | - | ||
SAS | 12 Gbps SAS card |
SP1X7SA3F | lsc | Supported (*11) | Supported (*11) | Supported (*12) | Supported (*12) | 2 sec. |
Oracle Solaris standard multi-path function (mpxio) |
FLASH | 3.2 TB Flash Accelerator Card | SP0X7Y42F | nvme | Not supported | Not supported | Not supported | Not supported | - | |
Flash Accelerator F320 card | SP1X7Y41F | nvme | Not supported | Not supported | Not supported | Not supported | - | ||
Infini Band |
Dual Port InfiniBand 4x QDR card | SP1X7BA12F | hermon | Not supported | Not supported | Not supported | Not supported | - | Oracle Solaris standard multi-path function (IPMP) |
Graphic | Graphics card | SP0X7GR1F | mko (TSI) | Not supported | Not supported | Not supported | Not supported | - | None |
-: Not applicable *1 The suspend/resume processing time means the time required for the suspend/resume processing per PCI card. Calculate the total suspend/resume processing time for the PCI cards to be used. *2 Supported by Oracle Solaris 11.2 SRU 11.2.2.8.0 and later and Oracle Solaris 10 1/13 150400-18 and later. *3 Add up the suspend/resume processing time for all the PCI cards mounted in the PCI expansion unit. *4 In a configuration that uses this card to assign SR-IOV (VF), DR is restricted. *5 In a configuration that uses this card to assign SR-IOV (VF), DR (active replacement) is restricted. *6 In 2x40 mode or 2x2x10 mode, the root domain must be restarted because the QCU tool is used to switch modes. *7 To use the Ethernet function (qlcnic driver) in Oracle Solaris 10, apply patch 149167-07 or later. *8 When the suspend/resume processing occurs as the port is being linked up, it takes about 3 seconds with a 1-port card and about 5 seconds with a 2-port card. *9 The processing time for each card is 10 seconds in Oracle Solaris 11.3 or later and Oracle Solaris 10 1/13 149173-06 or later. *10 Immediately after active addition of the PCI expansion unit, active addition of this card using PHP to the PCI expansion unit is not possible. *11 Active addition and active replacement of the PCI expansion unit are not possible. *12 Supported by Oracle Solaris 11.3 and later. |
Category | Name | Factory-Mounted Product ID When Shipped (Expanded-on-Site Product ID) |
Driver Name Software Product Name |
PHP: PCI Hot Plug | DR: Dynamic Reconfiguration | Path Redundancy Software |
||||
---|---|---|---|---|---|---|---|---|---|---|
Active Replacement | Active Addition | Active Replacement | Active Addition | Suspend/Resume Processing Time (*1) | ||||||
Link | Link card kit | 7105513 (7105576) |
None | Supported | Supported (*2) | Supported | Supported | 0.1 sec. (*3) | None | |
LAN | Sun Dual Port GbE PCIe 2.0 Low Profile Adapter, MMF | 7100482 (7100481) |
igb | Supported | Supported | To be supported | Oracle Solaris standard multi-path function (IPMP) | |||
Sun Quad Port GbE PCIe 2.0 Low Profile Adapter, UTP | 7100479 (7100477) |
igb | Supported | Supported | Supported | Supported | 0.8 sec. | |||
Sun Dual Port 10GBase-T Adapter | 7100563 (7100488) |
ixgbe | Supported | Supported | Supported (*4) | Supported (*4) | 0.4 sec. | |||
Sun Dual 10 GbE SFP+ PCIe 2.0 Low Profile Adapter | 1109A-Z (X1109A-Z) |
ixgbe | Supported | Supported | Supported (*4) | Supported (*4) | 0.4 sec. | |||
Oracle Quad Port 10GBase-T Adapter | 7111182 (7111181) | i40e | Supported | Not supported | Supported (*4) | Supported (*4) | 1.0 sec. | |||
Oracle Dual Port 25 Gb Ethernet Adapter | 7118015 (7118016) | bnxt | Not supported | Not supported | Supported (*5) | Supported | 0.1 sec. | |||
Oracle Quad 10 Gb or Dual 40 Gb Ethernet Adapter | 7114148 (7114134) | i40e | Supported (*6) | Not supported | Supported (*6) | Supported (*6) | 1.5 sec. | |||
FCoE/FC | Oracle Storage Dual-Port 32 Gb Fibre Channel PCIe Low Profile HBA, QLogic | 7115460 (7115462) | qlc | Supported | Supported | Not supported | Not supported | - | ||
Oracle Storage Dual-Port 32 Gb Fibre Channel PCIe Low Profile HBA, Emulex | 7115459 (7115461) | emlxs | Supported | Supported | Supported | Supported | 37 sec. (*7) |
|||
Sun Storage 16 Gb Fibre Channel PCIe Universal Host Bus Adapter, Qlogic | 7101673 (7101674) |
- | - | - | - | - | - | Oracle Solaris standard multi-path function (IPMP), and Oracle Solaris standard multi-path function (mpxio) | ||
with the 16 Gb FC short wave optics | with 7101675 (7101676) |
qlc | Supported | Supported (*8) | Supported | Supported | 20 sec. (*9) |
|||
with the 16 Gb FC long wave optics | with 7101679 (7101680) |
qlc | Supported | Supported (*8) | Supported | Supported | 20 sec. (*9) |
|||
with the 10 Gb FCoE short reach optics or TwinAx cables | with 7101677 (7101678) or TwinAx cables |
qlc, qlcnic | Supported | Supported (*8) | Supported (*10) | Supported (*10) | 20 sec. (*9) |
|||
Sun Storage 16 Gb Fibre Channel PCIe Universal Host Bus Adapter, Emulex | 7101683 (7101684) |
- | - | - | - | - | - | |||
with the 16 Gb FC short wave optics | with 7101685 (7101686) |
emlxs | Supported | Supported | Supported | Supported | 37 sec. (*7) |
|||
SAS | Oracle Storage 12 Gb SAS PCIe HBA, external: 8 port | 7110118 (7110119) | lsc | Supported (*11) | Supported (*11) | Supported (*12) | Supported (*12) | 2 sec. |
Oracle Solaris standard multi-path function (mpxio) | |
FLASH | Fujitsu 3.2 TB Flash Accelerator Card | 7119601 (7119603) | nvme | Not supported | Not supported | Not supported | Not supported | - | ||
Oracle Flash Accelerator F320 PCIe Card | 7113825 (7113826) | nvme | Not supported | Not supported | Not supported | Not supported | - | |||
IB | Oracle Dual Port QDR InfiniBand Adapter M3 | 7104073 (7104074) |
hermon | Not supported | Not supported | Not supported | Not supported | - | Oracle Solaris standard multi-path function (IPMP), and Oracle Solaris standard multi-path function (mpxio) | |
-: Not applicable *1 Apply the total suspend/resume processing time for the PCI cards to be used. *2 Supported by Oracle Solaris 11.2 SRU 11.2.2.8.0 and later and Oracle Solaris 10 1/13 150400-18 and later. *3 Add the suspend/resume processing time for all the PCI cards mounted in the PCI expansion unit to the suspend/resume processing time for the link card. *4 In a configuration that uses this card to assign SR-IOV (VF), DR is restricted. *5 In a configuration that uses this card to assign SR-IOV (VF), DR (active replacement) is restricted. *6 In 2x40 mode or 2x2x10 mode, the root domain must be restarted because the QCU tool is used to switch modes. *7 The processing time for each card is 10 seconds in Oracle Solaris 11.3 or later and Oracle Solaris 10 1/13 149173-06 or later. *8 Immediately after active addition of the PCI expansion unit, active addition of this card using PHP to the PCI expansion unit is not possible. *9 When the suspend/resume processing occurs as the port is being linked up, it takes about 3 seconds with a 1-port card and about 5 seconds with a 2-port card. *10 To use the Ethernet function (qlcnic driver) in Oracle Solaris 10, apply patch 149167-07 or later. *11 Active addition and active replacement of the PCI expansion unit are not possible. *12 Supported by Oracle Solaris 11.3 and later. |