Read this section before beginning any procedure. The following text provides safety precautions to follow when installing a Fujitsu product.
Safety Precautions
For your protection, observe the following safety precautions when setting up your equipment:
  1. Follow all cautions and instructions marked on the equipment.
  1. Ensure that the voltage and frequency of your power source match the voltage and frequency inscribed on the equipment's electrical rating label.
  1. Never push objects of any kind through openings in the equipment. Dangerous voltages may be present. Conductive foreign objects could produce a short circuit that could cause fire, electric shock, or damage to your equipment.
Symbols
The following symbols may appear in this book:
APL-caution Caution - There is a risk of personal injury and equipment damage. Follow the instructions.
APL-hot Caution - Hot surface. Avoid contact. Surfaces are hot and may cause personal injury if touched.
APL-hazard Caution - Hazardous voltages are present. To reduce the risk of electric shock and danger to personal health, follow the instructions.
Depending on the type of power switch your device has, one of the following symbols may be used:
APL-on On - Applies AC power to the system.
APL-off Off - Removes AC power from the system.
APL-standby Standby - The On/Standby switch is in the standby position.
Modifications to Equipment
Do not make mechanical or electrical modifications to the equipment. Fujitsu is not responsible for regulatory compliance of a modified Fujitsu product.
Placement of a Fujitsu Product
APL-caution Caution - Do not block or cover the openings of your Fujitsu product. Never place a Fujitsu product near a radiator or heat register. Failure to follow these guidelines can cause overheating and affect the reliability of your Fujitsu product.
Noise Level
Product: SPARC M12-1 (CPU: SPARC64 XII)
The following table shows the noise levels measured at an ambient temperature of 23ºC, in accordance with the requirements defined in ISO 7779.
SPARC M12-1:
  Operating Idling
LWAd1 7.4 B 7.4 B
LpAm2 58 dB 58 dB
1: LWAd indicates the declared A-weighted sound power level.
2: LpAm indicates the declared A-weighted emission sound pressure level at the bystander position.
Product: SPARC M12-2/M12-2S (CPU: SPARC64 XII)
The following table shows the noise levels measured at an ambient temperature of 23ºC, in accordance with the requirements defined in ISO 7779.
SPARC M12-2 (for 1-CPU configuration):
  Operating Idling
LWAd1 7.8 B 7.7 B
LpAm2 62 dB 61 dB
     
SPARC M12-2 (for 2-CPU configuration):
  Operating Idling
LWAd1 8.2 B 7.7 B
LpAm2 64 dB 61 dB
     
SPARC M12-2S (for 1-CPU configuration):
  Operating Idling
LWAd1 8.2 B 7.7 B
LpAm2 64 dB 61 dB
     
SPARC M12-2S (for 2-CPU configuration):
  Operating Idling
LWAd1 8.5 B 7.7 B
LpAm2 68 dB 61 dB
1: LWAd indicates the declared A-weighted sound power level.
2: LpAm indicates the declared A-weighted emission sound pressure level at the bystander position.
Product: SPARC M10-1/M10-4/M10-4S (CPU: SPARC64 X)
The following table shows the noise levels measured at an ambient temperature of 23ºC, in accordance with the requirements defined in ISO 7779.
SPARC M10-1:
  Operating Idling
LWAd1 6.8 B 6.8 B
LpAm2 50 dB 50 dB
     
SPARC M10-4/M10-4S (for 2-CPU configuration):
  Operating Idling
LWAd1 7.5 B 6.9 B
LpAm2 58 dB 56 dB
     
SPARC M10-4/M10-4S (for 4-CPU configuration):
  Operating Idling
LWAd1 8.2 B 6.9 B
LpAm2 64 dB 56 dB
1: LWAd indicates the declared A-weighted sound power level.
2: LpAm indicates the declared A-weighted emission sound pressure level at the bystander position.
Product: SPARC M10-1/M10-4/M10-4S (CPU: SPARC64 X+)
The following table shows the noise levels measured at an ambient temperature of 23ºC, in accordance with the requirements defined in ISO 7779.
SPARC M10-1:
  Operating Idling
LWAd1 7.4 B 7.4 B
LpAm2 58 dB 58 dB
     
SPARC M10-4/M10-4S (for 2-CPU configuration):
  Operating Idling
LWAd1 8.5 B 7.0 B
LpAm2 67 dB 57 dB
     
SPARC M10-4/M10-4S (for 4-CPU configuration):
  Operating Idling
LWAd1 9.0 B 7.0 B
LpAm2 74 dB 57 dB
1: LWAd indicates the declared A-weighted sound power level.
2: LpAm indicates the declared A-weighted emission sound pressure level at the bystander position.
SELV Compliance
Safety status of I/O connections comply to SELV requirements.
Power Cord Connection
APL-hazard Caution - Fujitsu products are designed to work with power systems having a grounded neutral (grounded return for DC-powered products). To reduce the risk of electric shock, do not plug Fujitsu products into any other type of power system. Contact your facilities manager or a qualified electrician if you are not sure what type of power is supplied to your building.
APL-hazard Caution - Not all power cords have the same current ratings. Do not use the power cord provided with your equipment for any other products or use. Household extension cords do not have overload protection and are not meant for use with computer systems. Do not use household extension cords with your Fujitsu product.
The following caution applies only to devices with a Standby power switch:
APL-hazard Caution - The power switch of this product functions as a standby type device only. The power cord serves as the primary disconnect device for the system. Be sure to plug the power cord into a grounded power outlet that is nearby the system and is readily accessible. Do not connect the power cord when the power supply has been removed from the system chassis.
The following caution applies only to devices with multiple power cords:
APL-hazard Caution: Shock hazard - For products with multiple power cords, all power cords must be disconnected to completely remove power from the system.
image
Battery Warning
APL-caution Caution - There is danger of explosion if batteries are mishandled or incorrectly replaced. On systems with replaceable batteries, replace only with the same manufacturer and type or equivalent type recommended by the manufacturer per the instructions provided in the product service manual. Do not disassemble batteries or attempt to recharge them outside the system. Do not dispose of batteries in fire. Dispose of batteries properly in accordance with the manufacturer's instructions and local regulations. Note that on Fujitsu motherboard units, there is a lithium battery molded into the real-time clock. These batteries are not customer replaceable parts.
System Unit Cover
You must remove the cover of your Fujitsu computer system unit to add cards or memory. Be sure to replace the cover before powering on your computer system.
APL-caution Caution - Do not operate Fujitsu products without the cover in place. Failure to take this precaution may result in personal injury and system damage.
Rack System Instructions
The following or similar rack-mount instructions are included with the installation instructions:
  1. Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
  1. Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.
  1. Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.
  1. Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
  1. Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (for example, use of power strips).
APL-caution Caution - Slide/rail mounted equipment must not be used as a shelf or workspace.
image
Rack System Warning
The following warnings apply to Racks and Rack Mounted systems.
APL-caution Caution - For safety, equipment should always be loaded from the bottom up. That is, install the equipment that will be mounted in the lowest part of the rack first, then the next higher systems, etc.
APL-caution Caution - To prevent the rack from tipping during equipment installation, the anti-tilt bar on the rack must be deployed.
APL-hot Caution - To prevent extreme operating temperature within the rack insure that the maximum temperature does not exceed the product's ambient rated temperatures.
APL-hot Caution - To prevent extreme operating temperatures due to reduced airflow consideration should be made to the amount of air flow that is required for a safe operation of the equipment.
APL-caution Caution - Take adequate precautions when moving a rack or library that contains rack-installed equipment. The weight of some rack equipment may have altered the rack or library center of gravity and could cause an overbalance/tip condition during a move.
Laser Compliance Notice
Fujitsu products that use laser technology comply with Class 1 or Class 1M laser requirements.

image
image
CD and DVD Devices
The following caution applies to CD, DVD, and other optical devices.
APL-caution Caution - Use of controls, adjustments, or the performance of procedures other than those specified herein may result in hazardous radiation exposure.