Test Charge=Basic Charge (30,000 JPY) + (Unit charge for test x test hours) + Option
| Reference Standards | Equipment (example) | Unit charge(JPY) per test hour |
|---|---|---|
Degradation in Characteristics under High temperature
|
Temperature chamber Temp:40 to 200degC Capacity:W600 x H600 x D600mm |
250 |
Degradation in Characteristics under low temperature
Degradation in Characteristics under damp heat conditions
|
Temperature/Humidity chamber Temp:-20degC to 100degC Relative Humidity:20 to 95%RH Capacity:W500 x H750 x D600mm |
350 |
Degradation in Characteristics under cyclic damp heat conditions
|
Temperature/Humidity chamber Temp:-20degC to 100degC Relative Humidity:20 to 95%RH Capacity:W500 x H750 x D600mm |
350 |
Degradation in Characteristics under thermal shock
|
Thermal shock tester Air type Temp:-65 to 0 / 60 to 200degC Capacity:W400 x H400 x D350mm Liquid type Temp:-65 to 0 / 50 to 200degC Capacity:W130 x H250 x D250mm (basket) Weight: 2kg |
600 For liquid type, cost of cool medium is added (300/cycle) |
Degradation in Characteristics under high pressure/humidity conditions
|
Pressure cooker (saturation/ non saturation) Temp:105 to 142.9degC Relative Humidity:75 to 100%RH Pressure: 0.020 to 0.196Mpa Capacity:φ250 x D300mm |
600 |
Degradation in Characteristics under vibration
|
Vibration tester Size: 200mm/edge Weight: 20kg Acceleration: 100G Wave frequency: 5 to 3000Hz |
11,000 |
If your request includes optional service, estimate will be otherwise issued.