Electron Probe X-ray Micro Analysis system irradiates finely focused electric beam on solid-state specimen to detect characteristic X-ray generated from the area electron beams reaches (of about 1µm). Elements in the target area of secondary electron image or in foreign material can be analyzed to identify their description, amount and distribution. This Analysis method is well-known for its excellent quantitative feature, compared to other solid-state surface analysis method.
There are 2 types of X-ray spectrometer; Wave length dispersion system (WDS) and Energy dispersion system (EDS). The former features high energy resolution and excellent quantitative analysis. In general, "EPMA" refers to the system applying WDS. With the latter, EDS, rapid Qualitative analysis is available. Typically, it is used by mounting on SEM.
PDF EPMA (222KB, A4)

JXA-8800RL
JXA-8800RL with EPMA LaB6 electron probe attached allow us to obtain fine electro beam with wich more microscopic area can be observed and analyzed.
In addition, with the higher performance of X-ray detector, sensitivity to trace of light element (C, O, N) has been greatly improved.

SEM image

X-ray mapping of Carbon
(Red and Yellow show the area with high density of Carbon)


Foreign material like the trace of liquid dry-out was identified as residual flux (Chlorine (Cl), Sn of solder).
Foreign material segregated like form of branch was identified as corrosion / segregation of solder constituent.
Solvent containing flux penetrated into gap between substrate and component, causing solder corrosion after voltage application on lead. Solder constitution was segregated in gaps between adjacent leads and electric short occurred.
Metal is segregated (migrated) in form of dendrite between adjacent conductive traces on PCB, from conductive trace with lower potential to that with higher potential.

Conduct Mono chrome mapping (characteristic X-ray) analysis by means of EPMA

Chorine (Cl) is observed in addition to Sn and Pb (Solder constituent) in Migration area
Electrolytic reaction has been accelerated between Water condensation and Cl in residual flux caused migration, and resulting electric short
In junction area of Cu pattern and Solder, Cu and solder may generate intermetallic compound that results in decreased junction force. Below EPMA image illustrates the statue of intermetallic compound generation in cross section of the junction area.