Crucial and Basic Precautions | Generally Precautions |
Capacitors
Directions for use
1. Polarity
FPCAP is a functional polymer capacitor with polarity, then do not reverse the polarity when using.
If it is used with the polarities reversed, swelled case, increased leakage current or a decreased life span may result.
2. Loading Voltages
Applying surge voltage is guaranteed, but over voltage exceeding the surge voltage may not be applied even for an instant as it may cause a short circuit or swelled case. Therefore, use the FPCAP within rated voltage when continuous load is applied.
3. Sudden charge and discharge
Sudden charge and discharge restricted (for maintenance of high-proof reliability).
A protection circuit is recommended for when a sudden charge or discharge causes excessive rush current because this is a
main cause of short circuits and large leakage current.
Use protection circuit when the rush current value is ten times larger than the allowable ripple current value and for circuits
whose rush current value exceeds 10A.
Be sure to insert a protection resister of about 1kΩ for charge and discharge when measuring the leakage current.
4. Soldering
The soldering conditions are to be within the range prescribed in the specification. If the specifications are not followed, there is the possibility of the appearance becoming defective and of increase of leak current and capacity reduction when soldering is conducted under conditions that are harsher than those stipulated.
5. PC board installations
The design must give consideration to the standard of lead position displacement giver in the specification.
The FPCAP may not be able to be inserted in the PC board if there is insufficient space.
If Lead wires are applied large stress like as tensile stress, inner contacts are given damages, then opened safety vent,
occurred short circuit or increased leakage current may result, when applying power.
6. Directions for use circuits
Since problems can be expected due to the leakage current fluctuations that occur during soldering and other processes, the FPCAP cannot be used to the following circuits.
- High impedance voltage retention circuits
- Coupling circuits
- Time constant circuits
- Circuits greatly affected by leakage current
- The circuits in which two or more of FPCAP is connected in series so as to raise the endurance voltage of them.
7. Using in industrial equipment
To insure reliability when the FPCAP is used in industrial equipment, design must allow for its capacitors, impedance, and other characteristics.
8. Using in equipment regarding human life
The above products are designed, developed and manufactured as contemplated for general use, including without limitation,
ordinary industrial use, general office use, personal use, and household use. But are not designed, developed and manufactured
as contemplated (1) for use accompanying fatal risks or dangers that, unless extremely high safety is secured, could have
a serious effect to the public, and could lead directly to death, personal injury, severe physical damage or other loss (i.e.,
nuclear reaction control in nuclear facility, aircraft flight control, air traffic control, mass transport control, medical
life support system, missile launch control in weapon system), or (2) for use requiring extremely high reliability (i.e.,
submersible repeater and artificial satellite).
You shall not use the above products for the above-mentioned uses.
If your equipment is likely to be used for the above-mentioned uses, please consult with our sales representative before use.
Fujitsu Media Devices shall not be liable against you and/or any third party for any claims or damages arising in connection
with the above-mentioned uses of the above products.
For details, refer to the Operating Precaution Guidelines for the EIAJ RC-2367 Electronic Device Solid aluminum Non-solid
Capacitor.
No part of this publication may be reproduced without prior written permission of the publisher.